Share:

AL 271 over STREAM

Map 

Coordinates:
+32.35000, -86.35000
32°21'00" N, 86°20'60" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:AL 271 over STREAM
Structure number:002767
Old structure number:0000027151M0170 (from 1992 edition)
Location:1.7 MI.N.OF MOBILE ROAD
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:9.8 ft. [3.0 m]
Total length:22.0 ft. [6.7 m]
Owner:City or Municipal Highway Agency [04]
Year built:1943
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: August 2014 

Status:Open, no restriction [A]
Average daily traffic:13,600 [as of 1988]
Truck traffic:2% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:53.2 tons [48.4 metric tons]
Inventory rating:31.9 tons [29.0 metric tons]
Sufficiency rating:79.0
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$1,215,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
August 201479.0Not deficient---13600
August 201279.0Not deficient---13600
August 201079.0Not deficient---13600
August 200869.6Not deficient---13600
July 200669.6Not deficient---13600
July 200469.6Not deficient---13600
April 200269.6Not deficient---13600
October 200069.6Not deficient---13600
September 199868.7Not deficient---13600
August 199668.3Not deficient---13600
May 199468.0Not deficient---13600
July 199265.0Not deficient---13600
April 199077.0Not deficient---13600