Share:

I65 SBL over EDGEMONT AVE

Map 

Coordinates:
+32.34419, -86.32526
32°20'39" N, 86°19'31" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:I65 SBL over EDGEMONT AVE
Structure number:009281
Location:1.2 MI.N.OF S.BYPASS
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:80.1 ft. [24.4 m]
Total length:203.1 ft. [61.9 m]
Roadway width between curbs:52.5 ft. [16.0 m]
Deck width edge-to-edge:55.1 ft. [16.8 m]
Vertical clearance below bridge:17.4 ft. [5.3 m]
Skew angle:33°
Owner:State Highway Agency [01]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:35,060 [as of 2008]
Truck traffic:16% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:72.6 tons [66.0 metric tons]
Inventory rating:43.5 tons [39.5 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:90.6
Estimated cost of work:$4,098,000

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:28,850 [as of 1997]
Truck traffic:14% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:47.9 tons [43.5 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:89.2