IN 85 over CHESTNUT STREET
Map
Coordinates:
+32.36576, -86.2793332°21'57" N, 86°16'46" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | IN 85 over CHESTNUT STREET |
| Structure number: | 010205 |
| Location: | 2.6 MI N OF I65 |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Interstate (Urban) [11] |
| Length of largest span: | 82.0 ft. [25.0 m] |
| Total length: | 409.1 ft. [124.7 m] |
| Roadway width between curbs: | 144.4 ft. [44.0 m] |
| Deck width edge-to-edge: | 150.9 ft. [46.0 m] |
| Vertical clearance below bridge: | 30.5 ft. [9.3 m] |
| Skew angle: | 42° |
| Owner: | State Highway Agency [01] |
| Year built: | 1970 |
| Year reconstructed: | 1994 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 6 |
| Main spans material: | Steel [3] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 112,900 [as of 2008] |
| Truck traffic: | 10% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 48.0 tons [43.6 metric tons] |
| Inventory rating: | 36.0 tons [32.7 metric tons] |
| Sufficiency rating: | 79.8 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $20,640,000 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 94,700 [as of 1997] |
| Truck traffic: | 8% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 47.9 tons [43.5 metric tons] |
| Inventory rating: | 36.0 tons [32.7 metric tons] |
| Sufficiency rating: | 82.6 |
| Recommended work: | Widening of existing bridge or other major structure without deck rehabilitation or replacement [33] |
| Estimated cost of work: | $7,512,000 |