Share:

4TH AVENUE NORTH over BRANCH

Map 

Coordinates:
+33.51667, -86.80000
33°31'00" N, 86°47'60" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:4TH AVENUE NORTH over BRANCH
Structure number:010421
Location:4TH AVE N * 6TH STREET
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:13.1 ft. [4.0 m]
Total length:28.9 ft. [8.8 m]
Skew angle:99°
Owner:City or Municipal Highway Agency [04]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: October 2014 

Status:Open, no restriction [A]
Average daily traffic:2,000 [as of 2014]
Truck traffic:10% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:36.0 tons [32.7 metric tons]
Inventory rating:26.0 tons [23.6 metric tons]
Sufficiency rating:76.3
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,317,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
October 201476.3Not deficient---2000
November 201263.2Not deficient---2000
November 201063.2Not deficient---2000
November 200863.2Not deficient---2000
October 200663.2Not deficient---2000
December 200463.2Not deficient---2000
July 200263.2Not deficient---2000
October 200063.2Not deficient---2000
October 199863.4Not deficient---2000
December 199663.2Not deficient---2000
November 199463.3Not deficient---2000
November 199257.9Not deficient---20000