Share:

I65 RAMP 52 over W.JEFF DAVIS AVE

Map 

Coordinates:
+32.36608, -86.32257
32°21'58" N, 86°19'21" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:I65 RAMP 52 over W.JEFF DAVIS AVE
Structure number:010690
Old structure number:00000I65510123C (from 1992 edition)
Location:I65 AND I85 INTERCHANGE
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:89.9 ft. [27.4 m]
Total length:299.9 ft. [91.4 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:29.9 ft. [9.1 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: May 2015 

Status:Open, would be posted or closed except for temporary shoring [D]
Average daily traffic:7,440 [as of 2013]
Truck traffic:12% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Equal to present desirable criteria [8]
Underclearances appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Scour condition:Bridge not over waterway. [N]
Operating rating:47.9 tons [43.5 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:62.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$2,278,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
May 201562.8Structurally deficientSatisfactoryPoorSatisfactory7440
May 201462.8Structurally deficientSatisfactoryPoorSatisfactory7440
May 201362.9Structurally deficientSatisfactoryPoorSatisfactory7302
March 201362.9Structurally deficientGoodPoorSatisfactory7302
March 201262.9Structurally deficientGoodPoorSatisfactory7124
March 201162.9Structurally deficientGoodPoorSatisfactory7124
May 200960.8Structurally deficientGoodPoorSatisfactory7777
May 200760.8Structurally deficientGoodPoorSatisfactory7543
May 200560.9Structurally deficientGoodPoorSatisfactory7257
March 200360.9Structurally deficientGoodPoorSatisfactory7017
March 200160.9Structurally deficientGoodPoorSatisfactory7017
April 199960.5Structurally deficientGoodPoorSatisfactory9693
April 199777.9Not deficientGoodFairSatisfactory9240
April 199589.3Not deficientGoodSatisfactorySatisfactory8610
March 199391.4Not deficientGoodGoodGood8000
January 199190.8Not deficientGoodGoodGood28210