Share:

I65 NBL over JEFF DAVIS AVE* RAMPS

Map 

Coordinates:
+32.36608, -86.32192
32°21'58" N, 86°19'19" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:I65 NBL over JEFF DAVIS AVE* RAMPS
Structure number:010873
Location:I65 AND I85 INTERCHANGE
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:125.0 ft. [38.1 m]
Total length:473.1 ft. [144.2 m]
Roadway width between curbs:51.2 ft. [15.6 m]
Deck width edge-to-edge:54.5 ft. [16.6 m]
Vertical clearance above deck:16.4 ft. [5.0 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1973
Year reconstructed:2009
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: December 2015 

Status:Open, no restriction [A]
Average daily traffic:37,200 [as of 2013]
Truck traffic:12% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:43.7 tons [39.7 metric tons]
Inventory rating:26.2 tons [23.8 metric tons]
Sufficiency rating:63.5
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$6,250,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
December 201563.5Not deficientSatisfactoryGoodGood37200
October 201363.5Not deficientGoodGoodGood37200
October 201173.6Not deficientGoodGoodGood35620
October 200970.2Functionally obsoleteGoodGoodGood38885
May 200785.2Not deficientGoodSatisfactoryGood37715
July 200585.3Not deficientGoodSatisfactoryGood36285
May 200385.5Not deficientGoodSatisfactoryGood35085
April 200185.5Not deficientGoodSatisfactoryGood35085
April 199984.6Not deficientGoodSatisfactoryGood33545
April 199784.6Not deficientGoodSatisfactoryGood33325
April 199585.5Not deficientGoodGoodGood31190
March 199389.8Not deficientGoodGoodGood27575