AL 79 over VILLAGE CK
Map
Coordinates:
+33.54864, -86.7805233°32'55" N, 86°46'50" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | AL 79 over VILLAGE CK |
| Structure number: | 010986 |
| Location: | .08 MI NO. I-59/20 |
| Purpose: | Carries highway over waterway |
| Route classification: | Other Principal Arterial (Urban) [14] |
| Length of largest span: | 74.2 ft. [22.6 m] |
| Total length: | 74.2 ft. [22.6 m] |
| Roadway width between curbs: | 124.0 ft. [37.8 m] |
| Deck width edge-to-edge: | 144.0 ft. [43.9 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1973 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Main span material: | Steel continuous [4] |
| Main span design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 53,140 [as of 2008] |
| Truck traffic: | 6% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 62.8 tons [57.1 metric tons] |
| Inventory rating: | 38.0 tons [34.5 metric tons] |
| Sufficiency rating: | 89.9 |
| Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
| Estimated cost of work: | $4,538,000 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 51,170 [as of 1997] |
| Truck traffic: | 6% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 62.9 tons [57.2 metric tons] |
| Inventory rating: | 38.0 tons [34.5 metric tons] |
| Sufficiency rating: | 91.2 |