Share:

I 59 over AVAITION AVE

Map 

Coordinates:
+33.55040, -86.74585
33°33'01" N, 86°44'45" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:I 59 over AVAITION AVE
Structure number:011095
Location:I59 & AVIATION AVE
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:78.1 ft. [23.8 m]
Total length:210.0 ft. [64.0 m]
Roadway width between curbs:63.3 ft. [19.3 m]
Deck width edge-to-edge:65.6 ft. [20.0 m]
Vertical clearance below bridge:25.9 ft. [7.9 m]
Skew angle:32°
Owner:State Highway Agency [01]
Year built:1974
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:40,780 [as of 2008]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:60.3 tons [54.8 metric tons]
Inventory rating:33.9 tons [30.8 metric tons]
Sufficiency rating:92.4
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$5,018,000

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:35,680 [as of 1996]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:47.9 tons [43.5 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:95.6