I565 over LIMESTONE SLOUGH
Map
Coordinates:
+34.63333, -86.8500034°37'60" N, 86°50'60" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | I565 over LIMESTONE SLOUGH |
| Structure number: | 014148 |
| Location: | 2.9 MI E JCT I65 & I565 |
| Purpose: | Carries highway over relief for waterway |
| Route classification: | Principal Arterial - Interstate (Urban) [11] |
| Length of largest span: | 41.0 ft. [12.5 m] |
| Total length: | 164.1 ft. [50.0 m] |
| Roadway width between curbs: | 40.0 ft. [12.2 m] |
| Deck width edge-to-edge: | 42.7 ft. [13.0 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1987 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 4 |
| Main spans material: | Prestressed concrete continuous [6] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 25,405 [as of 2008] |
| Truck traffic: | 10% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 73.9 tons [67.2 metric tons] |
| Inventory rating: | 46.0 tons [41.8 metric tons] |
| Sufficiency rating: | 94.6 |
| Estimated cost of work: | $2,637,000 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 18,980 [as of 1997] |
| Truck traffic: | 8% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 73.8 tons [67.1 metric tons] |
| Inventory rating: | 45.9 tons [41.7 metric tons] |
| Sufficiency rating: | 96.2 |