Share:

DEER CREEK DR over POND

Map 

Coordinates:
+32.33176, -86.14396
32°19'54" N, 86°08'38" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:DEER CREEK DR over POND
Structure number:016776
Location:0.5 S VAUGHN RD
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:7.9 ft. [2.4 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:70.9 ft. [21.6 m]
Deck width edge-to-edge:134.8 ft. [41.1 m]
Owner:City or Municipal Highway Agency [04]
Year built:1995
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2014 

Status:Open, no restriction [A]
Average daily traffic:50 [as of 1996]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:46.4 tons [42.2 metric tons]
Inventory rating:27.8 tons [25.3 metric tons]
Sufficiency rating:88.5
Estimated cost of work:$2,181,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
August 201488.5Not deficient---50
August 201288.5Not deficient---50
August 201088.5Not deficient---50
August 200874.1Not deficient---50
August 200674.1Not deficient---50
September 200474.1Not deficient---50
August 200274.1Not deficient---50
May 200074.1Not deficient---50
May 199974.2Not deficient---50
January 199773.9Not deficient---50