I-65 SOUTHBOUND over I-65 NORTHBOUND LANE
Map
Coordinates:
+33.51667, -86.8166733°31'00" N, 86°49'00" W
Source: National Bridge Inventory (2010 edition)
Information not verified. Use at your own risk.
Facts
| Name: | I-65 SOUTHBOUND over I-65 NORTHBOUND LANE |
| Structure number: | 018557 |
| Location: | SOUTHERN SECTION OF INTER |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Interstate (Urban) [11] |
| Length of largest span: | 140.1 ft. [42.7 m] |
| Total length: | 290.0 ft. [88.4 m] |
| Roadway width between curbs: | 77.1 ft. [23.5 m] |
| Deck width edge-to-edge: | 78.7 ft. [24.0 m] |
| Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
| Skew angle: | 60° |
| Owner: | State Highway Agency [01] |
| Year built: | 2002 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 3 |
| Main spans material: | Prestressed concrete continuous [6] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 135,060 [as of 2008] |
| Truck traffic: | 8% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 48.0 tons [43.6 metric tons] |
| Inventory rating: | 36.0 tons [32.7 metric tons] |
| Sufficiency rating: | 98.0 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $7,947,000 |