Facts
| Name: | CITY STREET over BOYD COOPER DRAINGE |
| Structure number: | 019302 |
| Location: | 0.1 MILE OF EASTCHASE |
| Purpose: | Carries highway over waterway |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 9.8 ft. [3.0 m] |
| Total length: | 40.0 ft. [12.2 m] |
| Roadway width between curbs: | 41.0 ft. [12.5 m] |
| Deck width edge-to-edge: | 89.9 ft. [27.4 m] |
| Vertical clearance below bridge: | 99.1 ft. [30.2 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 2002 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 4 |
| Main spans material: | Concrete continuous [2] |
| Main spans design: | Culvert [19] |
| Deck type: | Not applicable [N] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 550 [as of 2000] |
| Truck traffic: | 10% of total traffic |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Culvert condition: | No noticeable or noteworthy deficiencies which affect the condition of the culvert. Insignificant scrape marks caused by drift. [8] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 48.0 tons [43.6 metric tons] |
| Inventory rating: | 36.0 tons [32.7 metric tons] |
| Sufficiency rating: | 100.0 |
| Estimated cost of work: | $1,335,000 |