Share:

US 50 (I-305) WB over 6TH STREET & 8TH STREET

Map 

Coordinates:
+38.56667, -121.50333
38°34'00" N, 121°30'12" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:US 50 (I-305) WB over 6TH STREET & 8TH STREET
Structure number:24 0243L
Location:03-SAC-050-L.66-SAC
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:102.0 ft. [31.1 m]
Total length:923.9 ft. [281.6 m]
Roadway width between curbs:87.9 ft. [26.8 m]
Deck width edge-to-edge:89.9 ft. [27.4 m]
Vertical clearance below bridge:15.1 ft. [4.6 m]
Owner:State Highway Agency [01]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:9
Main spans material:Concrete continuous [2]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:102,500 [as of 2000]
Truck traffic:5% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:88.8 tons [80.7 metric tons]
Inventory rating:53.5 tons [48.6 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:83.9

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:85,650 [as of 1997]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:89.8 tons [81.6 metric tons]
Inventory rating:53.9 tons [49.0 metric tons]
Sufficiency rating:88.9

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:92,900 [as of 1990]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Very Good [8 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:89.1 tons [81.0 metric tons]
Inventory rating:53.5 tons [48.6 metric tons]
Sufficiency rating:91.0