Share:

N5-E50 CONNECTOR over S5-E50 CONN RP, BROADWAY

Map 

Coordinates:
+38.56667, -121.51111
38°34'00" N, 121°30'40" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:N5-E50 CONNECTOR over S5-E50 CONN RP, BROADWAY
Structure number:24 0269G
Location:03-SAC-005-22.41-SAC
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:140.1 ft. [42.7 m]
Total length:477.1 ft. [145.4 m]
Roadway width between curbs:32.2 ft. [9.8 m]
Deck width edge-to-edge:34.1 ft. [10.4 m]
Vertical clearance below bridge:17.1 ft. [5.2 m]
Owner:State Highway Agency [01]
Year built:1971
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:22,240 [as of 2002]
Truck traffic:2% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:82.7 tons [75.2 metric tons]
Inventory rating:51.8 tons [47.1 metric tons]
Sufficiency rating:93.9

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:20,500 [as of 1998]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Very Good [8 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:82.7 tons [75.2 metric tons]
Inventory rating:51.8 tons [47.1 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:91.0

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:13,000 [as of 1984]
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:82.2 tons [74.7 metric tons]
Inventory rating:51.5 tons [46.8 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:92.0