Share:

W580-E&W80 CONNCTR over UP RR,BNSF RY,AMTRAK,ETC

Map 

Coordinates:
+37.82694, -122.29000
37°49'37" N, 122°17'24" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:W580-E&W80 CONNCTR over UP RR,BNSF RY,AMTRAK,ETC
Structure number:33 0061R
Location:04-ALA-580-46.50R-OAK
Purpose:Carries highway overpass (fourth level) over highway and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:126.0 ft. [38.4 m]
Total length:3688.2 ft. [1124.1 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:32.8 ft. [10.0 m]
Vertical clearance above deck:15.4 ft. [4.7 m]
Vertical clearance below bridge:15.4 ft. [4.7 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1935
Year reconstructed:2006
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:51
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: May 2015 

Status:Open, no restriction [A]
Average daily traffic:220,000 [as of 2009]
Truck traffic:3% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:58.9 tons [53.5 metric tons]
Inventory rating:27.9 tons [25.4 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:54.0
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$31,399,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
May 201554.0Functionally obsoleteGoodGoodVery Good220000
August 201343.0Not deficientSatisfactoryFairGood220000
May 201139.0Not deficientSeriousFairGood220000
May 200949.0Not deficientSeriousSatisfactoryGood100000
May 200749.0Not deficientSeriousSatisfactoryGood100000
May 200540.0Not deficientSeriousFairGood100000
January 200542.0Not deficientSeriousFairGood100000
May 200353.0Not deficientSeriousSatisfactoryGood100000
May 200149.0Not deficientSeriousSatisfactoryGood133800
December 200054.0Not deficientSatisfactorySatisfactoryGood133800
20000.0Not applicable---136600
June 199754.0Functionally obsoleteSatisfactorySatisfactoryGood133800
May 199447.7Functionally obsoleteFairSatisfactoryFair141850
June 199247.7Functionally obsoleteFairSatisfactoryFair125000