Share:

THORNTON AVE over SR 84

Map 

Coordinates:
+37.54000, -122.06667
37°32'24" N, 122°04'00" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:THORNTON AVE over SR 84
Structure number:33 0508
Location:04-ALA-084-R3.75-NWK
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:111.9 ft. [34.1 m]
Total length:224.1 ft. [68.3 m]
Roadway width between curbs:69.9 ft. [21.3 m]
Deck width edge-to-edge:77.8 ft. [23.7 m]
Vertical clearance below bridge:16.1 ft. [4.9 m]
Skew angle:22°
Owner:State Highway Agency [01]
Year built:1983
Year reconstructed:1990
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Prestressed concrete continuous [6]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:29,535 [as of 2002]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:59.5 tons [54.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:96.2

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:10,000 [as of 1998]
Truck traffic:2% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:58.9 tons [53.5 metric tons]
Inventory rating:35.9 tons [32.6 metric tons]
Sufficiency rating:98.1

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:10,000 [as of 1990]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Very Good [8 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:58.4 tons [53.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:98.2