Facts 

Name:EMBARCADERO ST over LAKE MERRITT CANAL
Structure number:33C0030
Location:0.2 MI WEST OF 5TH ST
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:53.2 ft. [16.2 m]
Total length:478.0 ft. [145.7 m]
Roadway width between curbs:28.2 ft. [8.6 m]
Deck width edge-to-edge:37.1 ft. [11.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:9
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: November 2014 

Status:Open, no restriction [A]
Average daily traffic:7,342 [as of 2007]
Truck traffic:10% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:54.1 tons [49.2 metric tons]
Inventory rating:37.4 tons [34.0 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:77.1
Recommended work:Bridge deck rehabilitation with only incidental widening. [36]
Estimated cost of work:$2,766,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
November 201477.1Structurally deficientPoorVery GoodGood7342
January 201375.1Structurally deficientCriticalVery GoodGood7342
January 201175.4Structurally deficientSeriousVery GoodGood4530
December 200875.4Structurally deficientSeriousVery GoodGood4530
June 200775.4Structurally deficientSeriousVery GoodGood4530
March 200775.4Structurally deficientSeriousVery GoodGood4530
October 200575.4Structurally deficientSeriousVery GoodGood4530
December 200275.4Structurally deficientSeriousVery GoodVery Good4530
July 200177.4Structurally deficientPoorVery GoodVery Good4530
December 200077.4Structurally deficientPoorVery GoodVery Good4530
March 199977.4Structurally deficientPoorVery GoodVery Good4530
October 199877.4Structurally deficientPoorVery GoodVery Good4530
August 199580.6Not deficientSatisfactoryGoodVery Good4530
November 199380.6Not deficientSatisfactoryGoodVery Good4530
June 199180.6Not deficientSatisfactoryGoodVery Good4530