Share:

GOLD ST over GUADALUPE RIVER

Map 

Coordinates:
+37.42278, -121.97583
37°25'22" N, 121°58'33" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:GOLD ST over GUADALUPE RIVER
Structure number:37C0027
Location:0.4 MI N SH 237
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:60.0 ft. [18.3 m]
Total length:301.9 ft. [92.0 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:33.8 ft. [10.3 m]
Skew angle:
Owner:City or Municipal Highway Agency [04]
Year built:1964
Year reconstructed:1989
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:5
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: March 2016 

Status:Open, no restriction [A]
Average daily traffic:4,460 [as of 2005]
Truck traffic:3% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:59.8 tons [54.4 metric tons]
Inventory rating:39.2 tons [35.6 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:74.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,713,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
March 201674.8Structurally deficientPoorVery GoodGood4460
March 201474.8Structurally deficientPoorVery GoodGood4460
March 201274.8Structurally deficientPoorVery GoodGood4460
April 201072.7Structurally deficientImminent FailureVery GoodGood4460
December 200972.7Structurally deficientImminent FailureVery GoodGood4460
November 200772.7Structurally deficientImminent FailureVery GoodGood4460
November 200572.7Structurally deficientImminent FailureVery GoodGood4460
November 200477.7Structurally deficientImminent FailureVery GoodGood1740
March 200379.7Structurally deficientPoorVery GoodGood1740
January 200379.7Structurally deficientPoorVery GoodGood1740
November 200079.7Structurally deficientPoorVery GoodGood1740
December 199884.7Structurally deficientPoorVery GoodGood1740
February 199475.6Not deficientFairGoodFair1740
December 199275.6Not deficientFairGoodFair1740
May 199175.6Not deficientFairGoodFair1740