PENITENCIA CRK RD over UPPER PENITENCIA CREEK
Map
Coordinates:
+37.39389, -121.8119437°23'38" N, 121°48'43" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | PENITENCIA CRK RD over UPPER PENITENCIA CREEK |
| Structure number: | 37C0238 |
| Location: | NEAR ALUM ROCK |
| Purpose: | Carries highway over waterway |
| Route classification: | Collector (Urban) [17] |
| Length of largest span: | 22.0 ft. [6.7 m] |
| Total length: | 23.0 ft. [7.0 m] |
| Roadway width between curbs: | 25.3 ft. [7.7 m] |
| Deck width edge-to-edge: | 27.9 ft. [8.5 m] |
| Skew angle: | 29° |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1925 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Main span material: | Concrete [1] |
| Main span design: | Tee beam [04] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 500 [as of 1978] |
| Truck traffic: | 2% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 30.3 tons [27.5 metric tons] |
| Inventory rating: | 17.8 tons [16.2 metric tons] |
| Sufficiency rating: | 66.6 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 500 [as of 1998] |
| Truck traffic: | 2% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 21.9 tons [19.9 metric tons] |
| Inventory rating: | 14.0 tons [12.7 metric tons] |
| Sufficiency rating: | 48.2 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 500 [as of 1978] |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 19.8 tons [18.0 metric tons] |
| Inventory rating: | 12.4 tons [11.3 metric tons] |
| Sufficiency rating: | 48.6 |