OCALA STREET over SILVER CREEK
Map
Coordinates:
+37.34278, -121.8127837°20'34" N, 121°48'46" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | OCALA STREET over SILVER CREEK |
| Structure number: | 37C0241 |
| Location: | WEST OF WHITE RD |
| Purpose: | Carries highway and pedestrian walkway over waterway |
| Route classification: | Minor Arterial (Urban) [16] |
| Length of largest span: | 64.0 ft. [19.5 m] |
| Total length: | 65.9 ft. [20.1 m] |
| Roadway width between curbs: | 66.6 ft. [20.3 m] |
| Deck width edge-to-edge: | 80.1 ft. [24.4 m] |
| Skew angle: | 18° |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1976 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Main span material: | Concrete [1] |
| Main span design: | Box beam or girders - Multiple [05] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 12,720 [as of 1990] |
| Truck traffic: | 3% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 109.8 tons [99.8 metric tons] |
| Inventory rating: | 60.8 tons [55.3 metric tons] |
| Sufficiency rating: | 96.8 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 12,720 [as of 1998] |
| Truck traffic: | 3% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Inventory rating: | 60.8 tons [55.3 metric tons] |
| Sufficiency rating: | 96.8 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 12,720 [as of 1990] |
| Truck traffic: | 3% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Inventory rating: | 60.4 tons [54.9 metric tons] |
| Sufficiency rating: | 97.0 |