Share:

MERIDIAN AVE over ROSS CREEK

Map 

Coordinates:
+37.25889, -121.90083
37°15'32" N, 121°54'03" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:MERIDIAN AVE over ROSS CREEK
Structure number:37C0303
Location:NEAR HALBROOK DR
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:13.1 ft. [4.0 m]
Total length:25.9 ft. [7.9 m]
Roadway width between curbs:65.9 ft. [20.1 m]
Deck width edge-to-edge:90.2 ft. [27.5 m]
Owner:City or Municipal Highway Agency [04]
Year built:1976
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: November 2013 

Status:Open, no restriction [A]
Average daily traffic:25,300 [as of 2005]
Truck traffic:5% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:59.5 tons [54.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:93.4

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
November 201393.4Not deficient---25300
November 201164.8Structurally deficient---25300
December 200964.8Structurally deficient---25300
November 200764.8Structurally deficient---25300
November 200564.8Structurally deficient---25300
November 200364.8Structurally deficient---25330
November 200164.8Structurally deficient---25330
January 200064.8Structurally deficient---25330
July 199693.4Not deficient---25330
April 199393.2Not deficient---25330
February 199193.2Not deficient---25330