Share:

D ST over FRESNO RIVER

Map 

Coordinates:
+36.96778, -120.06278
36°58'04" N, 120°03'46" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:D ST over FRESNO RIVER
Structure number:41C0040
Location:N/O CENTRAL AVE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:32.2 ft. [9.8 m]
Total length:193.9 ft. [59.1 m]
Roadway width between curbs:51.8 ft. [15.8 m]
Deck width edge-to-edge:64.0 ft. [19.5 m]
Owner:City or Municipal Highway Agency [04]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:5,846 [as of 1976]
Truck traffic:2% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:60.9 tons [55.4 metric tons]
Inventory rating:36.7 tons [33.4 metric tons]
Sufficiency rating:97.5

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:5,846 [as of 1998]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:60.8 tons [55.3 metric tons]
Inventory rating:35.9 tons [32.6 metric tons]
Sufficiency rating:97.5

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:5,846 [as of 1976]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Scour calculation/evaluation has not been made. [6]
Operating rating:60.4 tons [54.9 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:97.6