Facts 

Name:W180-FULTON ST OFF over FULTON STREET
Structure number:42 0316K
Location:06-FRE-180-R57.24-FRE
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:147.0 ft. [44.8 m]
Total length:151.6 ft. [46.2 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:27.2 ft. [8.3 m]
Vertical clearance below bridge:17.4 ft. [5.3 m]
Skew angle:27°
Owner:State Highway Agency [01]
Year built:1995
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:101 [as of 1995]
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:59.5 tons [54.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:98.0

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:101 [as of 1995]
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:58.4 tons [53.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:99.0