Share:

VENTURA STREET over NB GOLDEN STATE-N99 ONRP

Map 

Coordinates:
+36.72528, -119.79194
36°43'31" N, 119°47'31" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:VENTURA STREET over NB GOLDEN STATE-N99 ONRP
Structure number:42 0385
Location:06-FRE-099-20.19-FRE
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:44.0 ft. [13.4 m]
Total length:91.9 ft. [28.0 m]
Roadway width between curbs:64.0 ft. [19.5 m]
Deck width edge-to-edge:76.1 ft. [23.2 m]
Vertical clearance below bridge:15.4 ft. [4.7 m]
Skew angle:10°
Owner:State Highway Agency [01]
Year built:1963
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:32,000 [as of 2001]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:76.8 tons [69.8 metric tons]
Inventory rating:45.9 tons [41.7 metric tons]
Sufficiency rating:86.8

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:8,830 [as of 1997]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:76.8 tons [69.8 metric tons]
Inventory rating:45.9 tons [41.7 metric tons]
Sufficiency rating:82.1

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:30,800 [as of 1990]
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:76.2 tons [69.3 metric tons]
Inventory rating:45.5 tons [41.4 metric tons]
Sufficiency rating:72.9