Facts 

Name:N FULTON AVE over DRY CREEK CANAL
Structure number:42C0210
Location:AT DUDLEY AVE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:19.0 ft. [5.8 m]
Total length:39.0 ft. [11.9 m]
Roadway width between curbs:44.3 ft. [13.5 m]
Deck width edge-to-edge:60.0 ft. [18.3 m]
Skew angle:45°
Owner:City or Municipal Highway Agency [04]
Year built:1911
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2015 

Status:Open, no restriction [A]
Average daily traffic:7,818 [as of 2009]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:25.6 tons [23.3 metric tons]
Inventory rating:15.3 tons [13.9 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:55.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$356,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
February 201555.7Functionally obsoleteGoodFairGood7818
March 201355.7Functionally obsoleteGoodFairGood7818
October 201162.8Not deficientGoodFairGood7818
December 200962.8Not deficientGoodFairGood8000
January 200862.8Not deficientGoodFairSatisfactory8000
November 200562.8Not deficientGoodFairSatisfactory8000
November 200362.8Not deficientGoodFairSatisfactory8000
November 200162.8Not deficientGoodFairSatisfactory8000
November 199938.5Structurally deficientGoodSeriousGood8000
February 199862.8Not deficientGoodFairGood8000
December 199662.8Not deficientGoodFairGood8000
September 199457.9Functionally obsoleteFairFairFair8000
April 199255.3Functionally obsoleteFairFairFair8000