Share:

EVANS AVE over COLONY MAIN CANAL

Map 

Coordinates:
+36.97250, -120.57250
36°58'21" N, 120°34'21" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:EVANS AVE over COLONY MAIN CANAL
Structure number:42C0506
Location:0.3 MI N/O SHAIN AVE
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:19.7 ft. [6.0 m]
Total length:41.0 ft. [12.5 m]
Roadway width between curbs:23.6 ft. [7.2 m]
Deck width edge-to-edge:24.0 ft. [7.3 m]
Skew angle:10°
Owner:County Highway Agency [02]
Year built:1925
Year reconstructed:1987
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:300 [as of 1999]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:109.8 tons [99.8 metric tons]
Inventory rating:58.9 tons [53.5 metric tons]
Sufficiency rating:84.4

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:300 [as of 1999]
Truck traffic:10% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Scour calculation/evaluation has not been made. [6]
Inventory rating:58.9 tons [53.5 metric tons]
Sufficiency rating:82.9

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:200 [as of 1988]
Truck traffic:10% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Scour calculation/evaluation has not been made. [6]
Inventory rating:58.4 tons [53.1 metric tons]
Sufficiency rating:87.7