RTE 110 over FLORENCE AVE
Map
Coordinates:
+33.97500, -118.2783333°58'30" N, 118°16'42" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | RTE 110 over FLORENCE AVE |
| Structure number: | 53 0918 |
| Location: | 07-LA-110-16.98-LA |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Interstate (Urban) [11] |
| Length of largest span: | 103.0 ft. [31.4 m] |
| Total length: | 106.0 ft. [32.3 m] |
| Roadway width between curbs: | 191.0 ft. [58.2 m] |
| Deck width edge-to-edge: | 191.0 ft. [58.2 m] |
| Vertical clearance below bridge: | 14.8 ft. [4.5 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1956 |
| Year reconstructed: | 1996 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18+Mod / HS 20+Mod [6] |
| Main span material: | Steel [3] |
| Main span design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 222,100 [as of 1997] |
| Truck traffic: | 6% of total traffic |
| Deck condition: | Poor [4 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 58.9 tons [53.5 metric tons] |
| Inventory rating: | 35.9 tons [32.6 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 94.0 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 222,100 [as of 1997] |
| Truck traffic: | 6% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 58.9 tons [53.5 metric tons] |
| Inventory rating: | 35.9 tons [32.6 metric tons] |
| Sufficiency rating: | 78.0 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $3,384,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 248,500 [as of 1990] |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 65.3 tons [59.4 metric tons] |
| Inventory rating: | 27.7 tons [25.2 metric tons] |
| Sufficiency rating: | 83.7 |