Share:

INTERSTATE 5 over SR 110 CON,ST,UP RR,RIV

Map 

Coordinates:
+34.08167, -118.22500
34°04'54" N, 118°13'30" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:INTERSTATE 5 over SR 110 CON,ST,UP RR,RIV
Structure number:53 1424
Location:07-LA-005-20.31-LA
Purpose:Carries highway over highway, waterway, and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:162.1 ft. [49.4 m]
Total length:2480.1 ft. [755.9 m]
Roadway width between curbs:108.9 ft. [33.2 m]
Deck width edge-to-edge:116.5 ft. [35.5 m]
Vertical clearance above deck:15.1 ft. [4.6 m]
Vertical clearance below bridge:15.4 ft. [4.7 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1962
Year reconstructed:1973
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:21
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: December 2014 

Status:Open, no restriction [A]
Average daily traffic:225,000 [as of 2009]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:78.9 tons [71.7 metric tons]
Inventory rating:47.9 tons [43.5 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:72.0
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$45,081,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
December 201472.0Functionally obsoleteSatisfactoryVery GoodVery Good225000
January 201371.0Functionally obsoleteFairSatisfactoryGood225000
May 201169.0Structurally deficientPoorSatisfactoryGood225000
December 200871.0Functionally obsoleteFairSatisfactoryGood237000
August 200771.0Functionally obsoleteFairSatisfactoryGood237000
May 200571.0Functionally obsoleteFairSatisfactoryGood237000
May 200373.0Functionally obsoleteFairSatisfactoryGood239000
January 200373.0Functionally obsoleteFairSatisfactoryGood239000
April 200171.0Functionally obsoleteFairSatisfactoryGood224800
March 199961.0Functionally obsoleteSatisfactoryFairGood224800
20000.0Not applicable---104800
January 199972.0Functionally obsoleteSatisfactoryGoodGood224800
February 199672.0Functionally obsoleteGoodGoodVery Good235200
October 199481.0Not deficientGoodGoodVery Good235200
January 198776.0Not deficientGoodGoodVery Good210900