E91-N110 CONNECTOR over SR 91, N110-W91 CONN
Map
Coordinates:
+33.87333, -118.2833333°52'24" N, 118°16'60" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | E91-N110 CONNECTOR over SR 91, N110-W91 CONN |
| Structure number: | 53 2665G |
| Location: | 07-LA-091-R6.37-LA |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
| Length of largest span: | 109.9 ft. [33.5 m] |
| Total length: | 1104.1 ft. [336.5 m] |
| Roadway width between curbs: | 34.5 ft. [10.5 m] |
| Deck width edge-to-edge: | 38.1 ft. [11.6 m] |
| Vertical clearance above deck: | 16.4 ft. [5.0 m] |
| Vertical clearance below bridge: | 17.7 ft. [5.4 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1985 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18+Mod / HS 20+Mod [6] |
| Number of main spans: | 11 |
| Main spans material: | Concrete continuous [2] |
| Main spans design: | Box beam or girders - Multiple [05] |
| Deck type: | Concrete Cast-in-Place [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 40,000 [as of 1998] |
| Truck traffic: | 2% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 59.4 tons [54.0 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 93.1 |
2000 Inspection
| Average daily traffic: | 4,700 [as of 1998] |
| Truck traffic: | 2% of total traffic |
| Evaluation: | Not applicable [N] |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 40,000 [as of 1985] |
| Deck condition: | Excellent [9 out of 9] |
| Superstructure condition: | Excellent [9 out of 9] |
| Substructure condition: | Excellent [9 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 58.4 tons [53.1 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 97.0 |