Facts 

Name:EB WEST CHANNEL RD over SANTA MONICA CYN CHANEL
Structure number:53C1252
Location:AT MESA RD
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:29.9 ft. [9.1 m]
Total length:37.1 ft. [11.3 m]
Roadway width between curbs:108.3 ft. [33.0 m]
Deck width edge-to-edge:220.2 ft. [67.1 m]
Skew angle:99°
Owner:City or Municipal Highway Agency [04]
Year built:1940
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2015 

Status:Open, no restriction [A]
Average daily traffic:16,239 [as of 2006]
Truck traffic:3% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:26.1 tons [23.7 metric tons]
Inventory rating:15.7 tons [14.3 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:66.6
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,273,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
September 201566.6Functionally obsoleteVery GoodVery GoodVery Good16239
September 201366.6Functionally obsoleteGoodGoodGood16239
August 201196.5Not deficientGoodGoodGood16239
December 200998.0Not deficientGoodGoodGood120
September 200797.0Not deficientGoodGoodGood120
June 200495.6Not deficientGoodGoodGood15000
June 200195.1Not deficientGoodGoodGood20500
May 199995.1Not deficient---20500
June 199795.1Not deficient---20500
November 199595.1Not deficientGoodGood-20500
September 199395.5Not deficientVery GoodVery GoodVery Good20500
September 199195.5Not deficientVery GoodVery GoodVery Good20500