WASHINGTON BLV over LOS ANGELES RIVER

Map 

Coordinates:
+34.01750, -118.22278
34°01'03" N, 118°13'22" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:WASHINGTON BLV over LOS ANGELES RIVER
Structure number:53C1375
Location:0.2 MI WEST OF SOTO ST
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:62.0 ft. [18.9 m]
Total length:312.0 ft. [95.1 m]
Roadway width between curbs:56.1 ft. [17.1 m]
Deck width edge-to-edge:70.9 ft. [21.6 m]
Skew angle:13°
Owner:City or Municipal Highway Agency [04]
Year built:1931
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Number of main spans:5
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2014 

Status:Open, no restriction [A]
Average daily traffic:20,077 [as of 2005]
Truck traffic:3% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:109.8 tons [99.8 metric tons]
Inventory rating:82.7 tons [75.2 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:74.4
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$3,457,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
April 201474.4Functionally obsoleteGoodGoodGood20077
April 201274.4Functionally obsoleteGoodGoodGood20077
May 201074.4Functionally obsoleteGoodGoodGood20077
April 200874.4Functionally obsoleteGoodGoodGood20077
December 200488.0Not deficientGoodGoodGood20077
October 199985.8Not deficientFairGoodGood27100
December 199785.8Not deficientFairGoodGood27100
May 199686.9Not deficientGoodGoodGood27100
April 199486.6Not deficientGoodGoodGood27100
April 199286.6Not deficientGoodGoodGood27100
April 199086.6Not deficientGoodGoodGood27100