Share:

ROUTE 805 over OTAY RIVER

Map 

Coordinates:
+32.59167, -117.03500
32°35'30" N, 117°02'06" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:ROUTE 805 over OTAY RIVER
Structure number:57 0631R
Location:11-SD-805-3.34-SD
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:107.9 ft. [32.9 m]
Total length:410.1 ft. [125.0 m]
Roadway width between curbs:78.1 ft. [23.8 m]
Deck width edge-to-edge:80.1 ft. [24.4 m]
Vertical clearance below bridge:47.9 ft. [14.6 m]
Skew angle:27°
Owner:State Highway Agency [01]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete continuous [2]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:73,500 [as of 1998]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:109.8 tons [99.8 metric tons]
Inventory rating:73.4 tons [66.7 metric tons]
Sufficiency rating:86.7

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:50,500 [as of 1997]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Scour calculation/evaluation has not been made. [6]
Inventory rating:72.8 tons [66.2 metric tons]
Sufficiency rating:93.3

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:44,500 [as of 1990]
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Scour calculation/evaluation has not been made. [6]
Inventory rating:72.3 tons [65.7 metric tons]
Sufficiency rating:94.7