168TH AVENUE over SOUTH PLATTE RIVER
Map
Coordinates:
+40.00039, -104.8269040°00'01" N, 104°49'37" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | 168TH AVENUE over SOUTH PLATTE RIVER |
| Structure number: | ADA168-12.05070 |
| Location: | .3 MI W OF HWY 85 |
| Purpose: | Carries highway over waterway |
| Route classification: | Minor Collector (Rural) [08] |
| Length of largest span: | 78.7 ft. [24.0 m] |
| Total length: | 245.4 ft. [74.8 m] |
| Roadway width between curbs: | 38.4 ft. [11.7 m] |
| Deck width edge-to-edge: | 41.0 ft. [12.5 m] |
| Skew angle: | 30° |
| Owner: | County Highway Agency [02] |
| Year built: | 1989 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Number of main spans: | 3 |
| Main spans material: | Prestressed concrete continuous [6] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 5,110 [as of 2008] |
| Truck traffic: | 9% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
| Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
| Operating rating: | 62.7 tons [57.0 metric tons] |
| Inventory rating: | 37.6 tons [34.2 metric tons] |
| Sufficiency rating: | 97.3 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 3,482 [as of 1998] |
| Truck traffic: | 9% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 61.4 tons [55.8 metric tons] |
| Inventory rating: | 36.6 tons [33.3 metric tons] |
| Sufficiency rating: | 98.5 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 1,919 [as of 1986] |
| Truck traffic: | 4% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 56.4 tons [51.3 metric tons] |
| Inventory rating: | 36.6 tons [33.3 metric tons] |
| Sufficiency rating: | 99.7 |