COLORADO AVENUE over MONUMENT CREEK
Map
Coordinates:
+38.83274, -104.8320438°49'58" N, 104°49'55" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | COLORADO AVENUE over MONUMENT CREEK |
| Structure number: | CSG-F.99-08.57A |
| Location: | JUST E OF I-25 |
| Purpose: | Carries highway and pedestrian walkway over waterway |
| Route classification: | Other Principal Arterial (Urban) [14] |
| Length of largest span: | 111.9 ft. [34.1 m] |
| Total length: | 330.7 ft. [100.8 m] |
| Roadway width between curbs: | 65.6 ft. [20.0 m] |
| Deck width edge-to-edge: | 95.5 ft. [29.1 m] |
| Skew angle: | 39° |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1998 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 3 |
| Main spans material: | Prestressed concrete continuous [6] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 17,576 [as of 2004] |
| Truck traffic: | 4% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 81.1 tons [73.7 metric tons] |
| Inventory rating: | 34.8 tons [31.6 metric tons] |
| Sufficiency rating: | 96.1 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 16,582 [as of 1998] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Excellent [9 out of 9] |
| Substructure condition: | Excellent [9 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 80.2 tons [72.9 metric tons] |
| Inventory rating: | 33.7 tons [30.6 metric tons] |
| Sufficiency rating: | 95.6 |