Share:

VINCENT DRIVE over COTTONWOOD CREEK

Map 

Coordinates:
+38.92856, -104.81051
38°55'43" N, 104°48'38" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:VINCENT DRIVE over COTTONWOOD CREEK
Structure number:CSG-H.01-15.11
Location:0.3 MI N OF DUBLIN BLVD.
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:50.9 ft. [15.5 m]
Total length:212.9 ft. [64.9 m]
Roadway width between curbs:19.7 ft. [6.0 m]
Deck width edge-to-edge:23.3 ft. [7.1 m]
Owner:City or Municipal Highway Agency [04]
Year built:1924
Historic significance:Bridge is on the National Register of Historic Places [1]
Number of main spans:4
Main spans material:Concrete continuous [2]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2014 

Status:Bridge closed to all traffic [K]
Average daily traffic:4,533 [as of 2013]
Truck traffic:6% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Operating rating:34.5 tons [31.4 metric tons]
Inventory rating:20.8 tons [18.9 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:34.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$5,863,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
March 201434.0Structurally deficientPoorPoorPoor4533
March 201231.5Structurally deficientPoorPoorFair5507
March 201031.5Structurally deficientPoorPoorFair5507
February 200849.1Functionally obsoleteFairFairFair5507
April 200649.4Functionally obsoleteFairFairFair7624
May 200449.4Functionally obsoleteFairFairFair7624
April 200256.8Functionally obsoleteSatisfactoryGoodSatisfactory9998
May 200044.6Functionally obsoleteFairSatisfactoryFair9998
October 199945.7Functionally obsoleteSatisfactoryGoodFair9998
October 199845.7Functionally obsoleteSatisfactoryGoodFair9998
July 199655.8Functionally obsoleteSatisfactoryGoodSatisfactory7803
June 199476.7Functionally obsoleteSatisfactoryGoodSatisfactory7803
September 199277.7Functionally obsoleteSatisfactoryGoodSatisfactory7803
July 199076.1Functionally obsoleteSatisfactoryGoodSatisfactory2946