Share:

ACADEMY BLVD over TEMPLETON GAP BASIN

Map 

Coordinates:
+38.88972, -104.75719
38°53'23" N, 104°45'26" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:ACADEMY BLVD over TEMPLETON GAP BASIN
Structure number:CSG-K.08-12.52
Location:300 FT S OF AUSTIN BLUFFS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:16.1 ft. [4.9 m]
Total length:43.6 ft. [13.3 m]
Deck width edge-to-edge:127.0 ft. [38.7 m]
Owner:City or Municipal Highway Agency [04]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: May 2014 

Status:Open, no restriction [A]
Average daily traffic:53,787 [as of 2013]
Truck traffic:3% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:39.9 tons [36.3 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:70.0
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
May 201470.0Not deficient---53787
May 201270.0Not deficient---62763
May 201070.0Not deficient---62763
March 200870.0Not deficient---62763