Share:

MAIZELAND ROAD over WEST FORK SAND CREEK

Map 

Coordinates:
+38.86786, -104.75441
38°52'04" N, 104°45'16" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:MAIZELAND ROAD over WEST FORK SAND CREEK
Structure number:CSG-K.10-11.00
Location:0.25 MI E OF ACADEMY BLVD
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:8.5 ft. [2.6 m]
Total length:26.9 ft. [8.2 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:68.9 ft. [21.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2014 

Status:Open, no restriction [A]
Average daily traffic:6,102 [as of 2013]
Truck traffic:6% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:39.9 tons [36.3 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:92.4

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
April 201492.4Functionally obsolete---6102
April 201292.3Functionally obsolete---7534
April 201092.3Functionally obsolete---7534
March 200892.3Functionally obsolete---7535
April 200692.3Functionally obsolete---7535
May 200492.3Functionally obsolete---7535
April 200292.8Functionally obsolete---4598
June 200092.5Functionally obsolete---4598
October 199992.3Functionally obsolete---4598
October 199892.3Functionally obsolete---4598
November 199691.6Functionally obsolete---9411
July 199479.3Not deficient---9411
October 199279.3Not deficient---9411
July 199094.3Not deficient---4748