Share:

CONSTITUTION AVE over SAND CREEK

Map 

Coordinates:
+38.87050, -104.71421
38°52'14" N, 104°42'51" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:CONSTITUTION AVE over SAND CREEK
Structure number:CSG-M.35-11.20
Location:0.3 MI E OF POWERS BLVD
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Rural) [09]
Length of largest span:14.1 ft. [4.3 m]
Total length:76.1 ft. [23.2 m]
Roadway width between curbs:116.8 ft. [35.6 m]
Deck width edge-to-edge:218.8 ft. [66.7 m]
Owner:City or Municipal Highway Agency [04]
Year built:1985
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: May 2014 

Status:Open, no restriction [A]
Average daily traffic:19,739 [as of 2013]
Truck traffic:4% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:64.9 tons [59.0 metric tons]
Inventory rating:38.9 tons [35.4 metric tons]
Sufficiency rating:97.2
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
May 201497.2Not deficient---19739
May 201096.7Not deficient---23347
April 200697.0Not deficient---21625
April 200297.1Not deficient---13764
May 200097.1Not deficient---13764
October 199997.1Not deficient---13764
October 199897.1Not deficient---13764