Share:

PARK AVE WEST over RR & S PLATTE RIVER

Map 

Coordinates:
+39.75879, -104.99293
39°45'32" N, 104°59'35" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:PARK AVE WEST over RR & S PLATTE RIVER
Structure number:D-03-V-030(A)
Location:WEST OF 22ND ST RAMP
Purpose:Carries highway and pedestrian walkway over railroad and waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:214.9 ft. [65.5 m]
Total length:1884.9 ft. [574.5 m]
Roadway width between curbs:96.1 ft. [29.3 m]
Deck width edge-to-edge:128.0 ft. [39.0 m]
Vertical clearance below bridge:25.6 ft. [7.8 m]
Skew angle:99°
Owner:City or Municipal Highway Agency [04]
Year built:1994
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:10
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:49,163 [as of 2009]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:63.1 tons [57.4 metric tons]
Inventory rating:38.8 tons [35.3 metric tons]
Sufficiency rating:93.3

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:32,281 [as of 1998]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:65.3 tons [59.4 metric tons]
Inventory rating:38.6 tons [35.1 metric tons]
Sufficiency rating:94.9