O' FALLON PARK RD over BEAR CREEK
Map
Coordinates:
+39.65461, -105.2881639°39'17" N, 105°17'17" W
Source: National Bridge Inventory (2010 edition)
Information not verified. Use at your own risk.
Facts
| Name: | O' FALLON PARK RD over BEAR CREEK |
| Structure number: | D-27-MP-110A |
| Location: | O' FALLON PARK |
| Purpose: | Carries highway over waterway |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 40.0 ft. [12.2 m] |
| Total length: | 45.6 ft. [13.9 m] |
| Roadway width between curbs: | 16.4 ft. [5.0 m] |
| Deck width edge-to-edge: | 20.0 ft. [6.1 m] |
| Vertical clearance below bridge: | 99.7 ft. [30.4 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 2003 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Main span material: | Concrete [1] |
| Main span design: | Arch - Deck [11] |
| Deck type: | Other [9] |
| Wearing surface: | Other [9] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 21 [as of 2008] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 89.8 tons [81.6 metric tons] |
| Inventory rating: | 74.6 tons [67.8 metric tons] |
| Sufficiency rating: | 80.3 |