NB PENA BLVD over SECOND CREEK TRIB
Map
Coordinates:
+39.83351, -104.7303139°50'01" N, 104°43'49" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | NB PENA BLVD over SECOND CREEK TRIB |
| Structure number: | D-31-PB-320 |
| Location: | WEST OF TOWER ROAD |
| Purpose: | Carries highway over waterway |
| Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
| Length of largest span: | 143.1 ft. [43.6 m] |
| Total length: | 148.3 ft. [45.2 m] |
| Roadway width between curbs: | 40.0 ft. [12.2 m] |
| Deck width edge-to-edge: | 42.7 ft. [13.0 m] |
| Skew angle: | 5° |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1993 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Main span material: | Prestressed concrete [5] |
| Main span design: | Box beam or girders - Multiple [05] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 23,255 [as of 2009] |
| Truck traffic: | 6% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 84.3 tons [76.6 metric tons] |
| Inventory rating: | 50.5 tons [45.9 metric tons] |
| Sufficiency rating: | 95.8 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 24,696 [as of 1998] |
| Truck traffic: | 6% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 83.2 tons [75.6 metric tons] |
| Inventory rating: | 49.5 tons [45.0 metric tons] |
| Sufficiency rating: | 97.7 |