I 70 ML over HAVANA ST, UP RR
Map
Coordinates:
+39.77579, -104.8658839°46'33" N, 104°51'57" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | I 70 ML over HAVANA ST, UP RR |
| Structure number: | E-17-JP |
| Location: | IN DENVER |
| Purpose: | Carries highway overpass over highway and railroad |
| Route classification: | Principal Arterial - Interstate (Urban) [11] |
| Length of largest span: | 54.1 ft. [16.5 m] |
| Total length: | 217.9 ft. [66.4 m] |
| Roadway width between curbs: | 139.1 ft. [42.4 m] |
| Deck width edge-to-edge: | 144.4 ft. [44.0 m] |
| Vertical clearance below bridge: | 16.1 ft. [4.9 m] |
| Skew angle: | 7° |
| Owner: | State Highway Agency [01] |
| Year built: | 1964 |
| Year reconstructed: | 1978 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 5 |
| Main spans material: | Steel continuous [4] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 183,000 [as of 2008] |
| Truck traffic: | 8% of total traffic |
| Deck condition: | Poor [4 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Poor [4 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 49.4 tons [44.9 metric tons] |
| Inventory rating: | 29.6 tons [26.9 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 43.8 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 144,468 [as of 1997] |
| Truck traffic: | 11% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 49.5 tons [45.0 metric tons] |
| Inventory rating: | 29.7 tons [27.0 metric tons] |
| Sufficiency rating: | 72.9 |
| Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
| Estimated cost of work: | $990,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 101,000 [as of 1988] |
| Truck traffic: | 9% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Poor [4 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 43.6 tons [39.6 metric tons] |
| Inventory rating: | 22.8 tons [20.7 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 35.0 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $990,000 |