I 25 ML NBND over NEVADA AVE.
Map
Coordinates:
+38.91528, -104.8163938°54'55" N, 104°48'59" W
Source: National Bridge Inventory (2010 edition)
Information not verified. Use at your own risk.
Facts
| Name: | I 25 ML NBND over NEVADA AVE. |
| Structure number: | I-17-NR |
| Location: | IN COLORADO SPRINGS |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Interstate (Urban) [11] |
| Length of largest span: | 130.6 ft. [39.8 m] |
| Total length: | 134.8 ft. [41.1 m] |
| Roadway width between curbs: | 71.9 ft. [21.9 m] |
| Deck width edge-to-edge: | 75.5 ft. [23.0 m] |
| Vertical clearance below bridge: | 22.0 ft. [6.7 m] |
| Skew angle: | 13° |
| Owner: | State Highway Agency [01] |
| Year built: | 2008 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 22.5 / HS 25 [9] |
| Main span material: | Prestressed concrete [5] |
| Main span design: | Box Beam or girders - Single or Spread [06] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 49,300 [as of 2007] |
| Truck traffic: | 7% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 93.4 tons [84.9 metric tons] |
| Inventory rating: | 93.4 tons [84.9 metric tons] |
| Sufficiency rating: | 90.5 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $2,168,000 |