Share:

ATLANTIC STREET over OXON RUN

Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:ATLANTIC STREET over OXON RUN
Structure number:0062
Location:ATLANTIC ST OVER OXON RUN
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:75.1 ft. [22.9 m]
Total length:79.1 ft. [24.1 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:56.1 ft. [17.1 m]
Skew angle:25°
Owner:State Highway Agency [01]
Year built:1953
Year reconstructed:2004
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: September 2015 

Status:Open, no restriction [A]
Average daily traffic:9,300 [as of 2007]
Truck traffic:1% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:77.9 tons [70.8 metric tons]
Inventory rating:46.9 tons [42.6 metric tons]
Sufficiency rating:96.1
Recommended work:Bridge deck rehabilitation with only incidental widening. [36]
Estimated cost of work:$1,500,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
September 201596.1Not deficientSatisfactorySatisfactoryGood9300
October 201376.9Functionally obsoleteSatisfactoryGoodGood9300
September 201176.9Not deficientGoodVery GoodGood9300
August 200976.9Not deficientGoodVery GoodGood9300
August 200776.8Functionally obsoleteGoodGoodSatisfactory9600
July 200576.8Functionally obsoleteVery GoodVery GoodVery Good9600
July 200265.6Functionally obsoleteGoodSatisfactoryFair9600
November 200065.6Functionally obsoleteGoodSatisfactoryFair9600
May 199865.6Functionally obsoleteGoodSatisfactoryFair9600
September 199669.2Functionally obsoleteSatisfactoryGoodSatisfactory9600
October 199465.9Functionally obsoleteSatisfactoryGoodFair9600
July 199264.9Functionally obsoleteFairFairSatisfactory9600
May 199076.1Functionally obsoleteFairSatisfactorySatisfactory9600