SR 600 US 92 over CSX RR
Map
Coordinates:
+27.99583, -82.3977827°59'45" N, 82°23'52" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | SR 600 US 92 over CSX RR |
| Structure number: | 100021 |
| Location: | 0.3MI WEST OF SR 583 |
| Purpose: | Carries highway and pedestrian walkway over railroad |
| Route classification: | Other Principal Arterial (Urban) [14] |
| Length of largest span: | 59.1 ft. [18.0 m] |
| Total length: | 167.3 ft. [51.0 m] |
| Roadway width between curbs: | 62.3 ft. [19.0 m] |
| Deck width edge-to-edge: | 70.5 ft. [21.5 m] |
| Vertical clearance below bridge: | 21.3 ft. [6.5 m] |
| Skew angle: | 41° |
| Owner: | State Highway Agency [01] |
| Year built: | 1936 |
| Year reconstructed: | 1954 |
| Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
| Design load: | M 18 / H 20 [4] |
| Number of main spans: | 3 |
| Main spans material: | Steel [3] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 48,500 [as of 2008] |
| Truck traffic: | 5% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 51.9 tons [47.2 metric tons] |
| Inventory rating: | 31.9 tons [29.0 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 86.6 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 38,500 [as of 1998] |
| Truck traffic: | 15% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 51.8 tons [47.1 metric tons] |
| Inventory rating: | 31.9 tons [29.0 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 85.1 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 37,290 [as of 1988] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 51.5 tons [46.8 metric tons] |
| Inventory rating: | 42.6 tons [38.7 metric tons] |
| Sufficiency rating: | 71.8 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $5,229,000 |