BROWARD ROAD over HIGHLANDS CREEK
Map
Coordinates:
+30.42333, -81.6794430°25'24" N, 81°40'46" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | BROWARD ROAD over HIGHLANDS CREEK |
| Structure number: | 724330 |
| Location: | 1 MI E OF LEM TURNER RD |
| Purpose: | Carries highway over waterway |
| Route classification: | Collector (Urban) [17] |
| Length of largest span: | 42.7 ft. [13.0 m] |
| Total length: | 42.7 ft. [13.0 m] |
| Roadway width between curbs: | 41.3 ft. [12.6 m] |
| Deck width edge-to-edge: | 44.3 ft. [13.5 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1986 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Main span material: | Prestressed concrete [5] |
| Main span design: | Slab [01] |
| Deck type: | Concrete Cast-in-Place [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 8,501 [as of 2009] |
| Truck traffic: | 5% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 52.8 tons [48.0 metric tons] |
| Inventory rating: | 45.1 tons [41.0 metric tons] |
| Sufficiency rating: | 83.6 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 8,501 [as of 1999] |
| Truck traffic: | 5% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 52.8 tons [48.0 metric tons] |
| Inventory rating: | 45.1 tons [41.0 metric tons] |
| Sufficiency rating: | 97.0 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 8,501 [as of 1991] |
| Truck traffic: | 5% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 52.5 tons [47.7 metric tons] |
| Inventory rating: | 44.6 tons [40.5 metric tons] |
| Sufficiency rating: | 97.7 |