Share:

I-95 over NW 95 ST

Map 

Coordinates:
+25.86194, -80.20806
25°51'43" N, 80°12'29" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:I-95 over NW 95 ST
Structure number:870434
Location:I-95 & NW 95 ST(MP 8.336)
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:51.8 ft. [15.8 m]
Total length:188.0 ft. [57.3 m]
Roadway width between curbs:168.6 ft. [51.4 m]
Deck width edge-to-edge:174.5 ft. [53.2 m]
Vertical clearance below bridge:15.4 ft. [4.7 m]
Owner:State Highway Agency [01]
Year built:1961
Year reconstructed:1991
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:256,000 [as of 2008]
Truck traffic:4% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:61.6 tons [56.0 metric tons]
Inventory rating:38.1 tons [34.6 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:79.4

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:106,750 [as of 1999]
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:71.5 tons [65.0 metric tons]
Inventory rating:42.9 tons [39.0 metric tons]
Sufficiency rating:88.7

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:105,661 [as of 1988]
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:61.4 tons [55.8 metric tons]
Inventory rating:55.4 tons [50.4 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:81.5
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$3,000