Share:

I-75 over M-9208 W.PACES FERRY RD.

Map 

Coordinates:
+33.84878, -84.43103
33°50'56" N, 84°25'52" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:I-75 over M-9208 W.PACES FERRY RD.
Structure number:000000012101520
Location:IN N ATLANTA
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:93.8 ft. [28.6 m]
Total length:93.8 ft. [28.6 m]
Roadway width between curbs:174.9 ft. [53.3 m]
Deck width edge-to-edge:180.8 ft. [55.1 m]
Vertical clearance below bridge:17.1 ft. [5.2 m]
Skew angle:10°
Owner:State Highway Agency [01]
Year built:1985
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:185,420 [as of 2007]
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:98.0 tons [89.1 metric tons]
Inventory rating:69.3 tons [63.0 metric tons]
Sufficiency rating:85.0

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:194,900 [as of 1998]
Truck traffic:4% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:75.2 tons [68.4 metric tons]
Inventory rating:44.6 tons [40.5 metric tons]
Sufficiency rating:79.0

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:154,950 [as of 1990]
Truck traffic:4% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:60.4 tons [54.9 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:92.0