Share:

COURTLAND STREET over M9003 DECATUR ST-CSX RR

Map 

Coordinates:
+33.75227, -84.38651
33°45'08" N, 84°23'11" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:COURTLAND STREET over M9003 DECATUR ST-CSX RR
Structure number:000000012103220
Location:IN ATLANTA
Purpose:Carries highway and pedestrian walkway over highway and railroad
Route classification:Minor Arterial (Urban) [16]
Length of largest span:84.0 ft. [25.6 m]
Total length:1122.1 ft. [342.0 m]
Roadway width between curbs:44.9 ft. [13.7 m]
Deck width edge-to-edge:60.0 ft. [18.3 m]
Vertical clearance below bridge:20.7 ft. [6.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1906
Year reconstructed:1995
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Prestressed concrete [5]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2014 

Status:Posted for load [P]
Average daily traffic:16,020 [as of 2011]
Truck traffic:1% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:29.7 tons [27.0 metric tons]
Inventory rating:22.8 tons [20.7 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:51.4
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$10,163,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
October 201451.4Functionally obsoleteSatisfactoryFairFair16020
October 201251.4Functionally obsoleteFairFairFair16020
October 201051.3Functionally obsoleteFairFairFair17480
December 200851.3Functionally obsoleteFairFairFair17480
October 200651.2Functionally obsoleteFairFairFair18150
December 200451.3Functionally obsoleteFairFairFair17650
January 200350.1Not deficientFairFairFair29600
January 200150.0Not deficientFairFairFair30760
February 19995.0Not deficientFairFairFair30760
April 19972.0Not deficientFairPoorFair30760
January 19955.0Structurally deficientFairPoorFair30760
March 19936.0Structurally deficientSatisfactorySeriousSerious30760
March 19916.0Structurally deficientSatisfactorySeriousSerious26703