Share:

MACON DRIVE over SOUTH RIVER

Map 

Coordinates:
+33.69384, -84.39074
33°41'38" N, 84°23'27" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:MACON DRIVE over SOUTH RIVER
Structure number:000000012103770
Location:IN ATLANTA
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:34.1 ft. [10.4 m]
Total length:34.1 ft. [10.4 m]
Roadway width between curbs:28.2 ft. [8.6 m]
Deck width edge-to-edge:40.7 ft. [12.4 m]
Skew angle:30°
Owner:City or Municipal Highway Agency [04]
Year built:1936
Year reconstructed:1997
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2014 

Status:Open, no restriction [A]
Average daily traffic:4,620 [as of 2011]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:65.3 tons [59.4 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:80.7
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$199,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
October 201480.7Not deficientGoodSatisfactoryGood4620
October 201280.7Not deficientSatisfactorySatisfactoryGood4620
October 201080.8Not deficientGoodGoodVery Good4340
December 200880.8Not deficientGoodGoodVery Good4340
November 200680.7Not deficientGoodGoodVery Good4990
December 200480.7Not deficientGoodGoodVery Good4850
October 200280.7Not deficientGoodGoodVery Good4700
December 200078.3Not deficientGoodGoodVery Good11370
January 199978.3Not deficientGoodGoodVery Good11370
April 199778.4Not deficientVery GoodVery GoodVery Good10480
January 199567.9Functionally obsoleteSatisfactorySatisfactorySatisfactory10460
February 199371.4Functionally obsoleteSatisfactorySatisfactorySatisfactory9870
February 199150.0Structurally deficientSatisfactorySatisfactoryFair9250